INTRODUCTION
solar air conditioners operate directly using solar energy and utility energy , no need battery.When the sun is shining, it is powered by the solar source completely; when the sun is weak, it is powered by the solar and utility together,the whole system with hybrid design,can work online sharing with solar and utility energy.
Areas without electricity, low power,unstable power grids,and high electricity prices where air conditioner is in demand.
Brand:
JntechItem NO.:
12000~24000BTUProduct Origin:
Hefei Anhui ChinaColor:
whiteShipping Port:
Nanjing, Shanghai, NingboINTRODUCTION
solar air conditioners operate directly using solar energy and utility energy , no need battery.When the sun is shining, it is powered by the solar source completely; when the sun is weak, it is powered by the solar and utility together,the whole system with hybrid design,can work online sharing with solar and utility energy.
Areas without electricity, low power,unstable power grids,and high electricity prices where air conditioner is in demand.
Solar& AC hybrid Conditioner system suggested configuration |
||||
Model |
Power input (w) average |
Work Time (h) solar time |
Solar Panel |
Application area (m²) |
JNSAC-HS-12000BTU |
800 |
9 |
340W*4 |
15~20 |
JNSAC-HS-18000BTU |
1300 |
8 |
340W*6 |
20~30 |
JNSAC-HS-24000BTU |
1700 |
8 |
340W*8 |
32~42 |
Model |
Unit |
|
JNSAC12000-V2 |
JNSAC18000-V2 |
JNSAC24000-V2 |
Power Supply |
AC Power |
Ph-V-Hz |
1Ph 208V-240V/50-60HZ |
1Ph 208V-240V/50-60HZ |
1Ph 208V-240V/50-60HZ |
DC Power (PV in Series) |
V |
80-380V |
80-380V |
80-380V |
|
DC Power Current |
A |
</=12A |
</=12A |
</=12A |
|
Adviced Solar Panel |
Pcs |
(3-4)*330W in series |
(3-6)*330W in series |
(3-8)*330W in series |
|
Rated Cooling |
Capacity |
W |
3510(900-3900) |
5070(1200-6000) |
6450(1800-7900) |
BTU |
12000(3000-13300) |
17300(4100-20400) |
22000(6100-27000) |
||
Power input |
W |
940(190-1270) |
1400(220-2100) |
1790(300-3200) |
|
Rated Heating |
Capacity |
W |
4100(1000-4500) |
6100(1200-6800) |
7800(1800-9100) |
Power input |
W |
1170(190-1700) |
1770(220-2500) |
2290(300-3500) |
|
T1 EER (W/W)/ (BTU/W) |
/ |
3.75/12.75 |
3.60/12.35 |
3.60/12.30 |
|
COP (W/W)/ (BTU/W) |
/ |
3.50/11.95 |
3.45/11.75 |
3.40/11.60 |
|
Dehumidification capacity |
L/h |
1.3 |
1.7 |
2.5 |
|
Indoor noise level (Turbo) |
dB(A) |
42.5 |
46 |
50 |
|
Indoor unit |
Dimension(W×H×D) |
mm |
840×205×295 |
1080×330×237 |
1080×330×237 |
Packing (W×H×D) |
mm |
920×290×360 |
1140×300×382 |
1140×300×382 |
|
Net weight/Gross weight |
Kg |
9.0/12.5 |
15.0/18.5 |
15.0/18.5 |
|
Outdoor noise level |
dB(A) |
52 |
55 |
58 |
|
Outdoor unit |
Dimension(W×H×D) |
mm |
802×564×323 |
802×564×323 |
900×700×337 |
Packing (W×H×D) |
mm |
910×622×405 |
910×622×405 |
1006×755×418 |
|
Net/Gross weight |
Kg |
33.5/37.5 |
37/42.0 |
50/54.5 |
|
Refrigerant type |
/ |
R410A |
R410A |
R410A |
|
Max Design pressure |
MPa |
4.3/1.5 |
4.3/1.5 |
4.3/1.5 |
|
Refrigerant copper pipe |
Gas side/Liquid side (inch) |
inch |
3/8 1/4 |
1/2 1/4 |
1/2 1/4 |
Max. refrigerant pipe length |
m |
15 |
20 |
25 |
|
Max. difference in level |
m |
8 |
10 |
10 |
|
Refrigerant connction copper pipe length |
m |
3 |
4 |
4 |
|
Connection wire length |
m |
4 |
5 |
5 |
|
Electronic Expansion Valve |
/ |
Yes |
Yes |
Yes |
|
Loading QTY 40" Hq/ 20"GP |
Sets |
200/85 |
160/75 |
115/50 |
|
Application area |
m² |
15~20 |
20~30 |
32~42 |