The system is composed of PV module, Solar Off grid inverter, MPPT charge controller and Battery pack. Solar Off grid inverter is core device of PV power sysem, it converts DC power produced by solar panels to AC power to provide electric energy for applications. MPPT charge controller charge the solar electricity into batteries. When solar energy is not enough for loads, or at night, the battery pack will be discharge to replenish energy for loads.
Brand:
JntechItem NO.:
JNF3KLF24VPayment:
FOBProduct Origin:
Anhui,ChinaColor:
buleShipping Port:
shanghai,ningbo,nanjingLead Time:
7 days
Introduction
High Integrated with inverter, AC charger, solar charge controller and AC by pass.
Intelligent management system of AC charger and PV charging controller, AC optional and AC output self-contained energy management system, which can ensure the normal power consumption and reduce the cost of electricity bill.
Averagely, Jntech solar off grid solution could save 1.5 kWh to 2 kWh per hour in sunshine duration, which means, approximately, with a Jntech solar off grid solution we can save 16 kWh a day with 8 hours sunshine duration. With the world average on-grid electricity price of $0.15 per kWh, a Jntech solar off grid solution could save a minimum of $2.4 a day. After 3 years of using the Jntech solar off grid solution, the money you saved on the electricity bill could easily cover the cost of the Jntech solar off grid solution. Of which, in another word, after using the Jntech solar off grid solution for 3 years, the longer you use it, the more you save on electricity bill!
Subject/mode
JNF3KLF24V-V2
JNF3KLF48V-V2
JNF4KLF48V-V2
JNF5KLF48V-V2
PV input
PV max. input dc voltage
150Vdc
Recommended PV Capacity
3500W
5000W
7000W
7000W
MPPT range
35~145Vdc
65~145Vdc
65~145Vdc
65~145Vdc
Storage battery
Rated voltage
24Vdc
48Vdc
48Vdc
48Vdc
Max. charging current
80A
60A
80A
80A
Charging efficiency
≥97%
Battery type
Gel/lithium
Inverter output
Rated output capacity
3000VA
3000VA
4000VA
5000VA
Rated output power (linear load)
3000W
3000W
4000W
5000W
Output voltage
220Vac
220Vac
220Vac
220Vac
Rated frequency
50/60Hz (±3%)
Standby loss
≤10W
Max. efficiency
93%
Output waveform
Pure sine wave
THD
<3%
Rated current
13.5A
13.5A
18A
22.5A
Peak current factor
3:1
Overload
125%@rated power, 70s;150%@rated ,20s; 200%@rated ,5s;over 300%@rated,0s.
Grid input
Grid input voltage
230Vac±20%
Grip input frequency
50/60Hz (±3%)
Max. charging current
30A
40A
40A
40A
Power grid bypass
Allowed input voltage
230Vac±20%
230Vac±20%
230Vac±20%
230Vac±20%
Switching time
<10ms
Machine parameters
Dimension(W/H/D)
440mm*370mm*190mm
Weight
28Kg
28kg
30kg
33kg
Others parameters
Protection lever
IP20
Noise
<60dB
Cooling method
Forced air cooling
Working temperature
-20~+50℃
Storage temperature
-25~+70℃
Status indicator
LCD+LED
Interface
RS485/CAN (Optional)
Altitude height
2000m(>2000m derating)