Solar pump inverter obtains direct current energy from solar cells, and converts it into electric energy to drive the water pump. According to the intensity of sunlight, take use of MPPT algorithm, the solar pump inverter adjusts the output frequency to make maximum use of solar energy.
Brand:
JntechItem NO.:
JNP3KL-V6Product Origin:
Anhui,ChinaColor:
BlueShipping Port:
Nanjing, Ningbo, Shanghai,Shenzhen,GuangzhouLead Time:
7DaysINTRODUCTION
This soalr pump inverter is specially designed for field irrigation,drinking water in small towns pump system,using hybrid design with solar and utility/DG Energy online complementation.
Features:
8.Fully automatic operation control, soft start and soft stop,one key to start.
Model |
JNP2K2L-V6
|
JNP3KL-V6
|
JNP3K7L-V6
|
JNP4KL-V6
|
PV Input |
|
|
|
|
D.C. Max. Input Voltage | 480V | 480V | 480V | 480V |
Recommended MPPT Voltage |
200~450Vdc
|
200~450Vdc
|
200~450Vdc
|
200~450Vdc
|
D.C. Max. Input Current | 15A | 30A | 30A | 30A |
Max. MPPT Effiffifficiency | >99% | >99% | >99% | >99% |
Number of String | 1 | 1 | 1 | 1 |
Utility/diesel input
|
|
|
|
|
Voltage |
198-264Vac,1PH
|
198~264Vac,1PH | 198~264Vac,1PH | 198~264Vac,1PH |
Frequency | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) | 50Hz/60Hz(±3%) |
A.C. Output |
|
|
|
|
Max. matching motor power
|
2.2kW
|
3kW(3PH) or 2.2kW(1PH)
|
3.7kW(3PH) or2.2kW(1PH)
|
4kW(3PH) or 2.2kW(1PH)
|
Rated Output Voltage | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) | 220/230Vac (1PH or 3PH) |
Output Frequency Range | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz | 0~50/60Hz |
Max.Output Current | 15A | 16A | 17A | 18A |
System |
|
|
|
|
Protection Level | IP65 | IP65 | IP65 | IP65 |
Operating Temperature | -25~60℃ | -25~60℃ | -25~60℃ | -25~60℃ |
Cooling Way | Nature cooling | Nature cooling | Nature cooling | Nature cooling |
Display | RS485/GPRS | RS485/GPRS | RS485/GPRS | RS485/GPRS |
Altitude | 3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
3000m, above3000m need derate operarting |
Noise Emission | <50dB | <50dB | <50dB | <50dB |
Compliance |
EN 50178; IEC/EN 62109-1;IEC61000
|
EN 50178; IEC/EN 62109-1;IEC61000
|
EN 50178; IEC/EN 62109-1;IEC61000
|
EN 50178; IEC/EN 62109-1;IEC61000
|
Dimension(W/H/D) |
278/370/125(mm)
|
278/370/125(mm)
|
278/370/125(mm)
|
278/370/125(mm)
|
Weight | 11.8kg | 11.8kg | 11.8kg | 11.8kg |
ISO9001, IS014001, OHSAS18001,TUV,CE,AAA credit management system,Third level qualification of power project construction, National high-tech enterprises