Solar pump inverter obtains direct current energy from solar cells, and converts it into electric energy to drive the water pump. According to the intensity of sunlight, take use of MPPT algorithm, the solar pump inverter adjusts the output frequency to make maximum use of solar energy.
Brand:
JntechItem NO.:
JNP5K5H-V6Product Origin:
Anhui,ChinaColor:
BlueShipping Port:
Nanjing, Ningbo, Shanghai,Shenzhen,GuangzhouLead Time:
7DaysINTRODUCTION
This soalr pump inverter is specially designed for field irrigation,drinking water in small towns pump system,using hybrid design with solar and utility/DG Energy online complementation.
Features:
8.Fully automatic operation control, soft start and soft stop,one key to start.
Item\ Model
|
JNP2K2H-V6
|
JNP3KH-V6
|
JNP3K7H-V6 |
JNP4KH-V6 |
JNP5K5H-V6 |
JNP7K5H-V6 |
DC input
|
|
|
|
|
|
|
Max. input DC voltage
|
880V
|
880V |
880V |
880V |
880V |
880V |
Recommended MPPT voltage
|
460~850V
|
460~850V |
460~850V |
460~850V |
460~850V |
460~850V |
Max. input DC current
|
15A
|
15A |
15A |
15A |
30A |
30A |
MPPT efficiency
|
>99%
|
>99% |
>99% |
>99% |
>99% |
>99% |
Max. input DC voltage
|
1 | 1 | 1 | 1 | 1 | 1 |
Utility/diesel input parameters
|
|
|
|
|
|
|
VDC
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
Frequency
|
50Hz/60Hz
|
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
AC output side
|
|
|
|
|
|
|
Max. matching motor power
|
2.2kW
|
3kW
|
3.7kW |
4kW |
5.5kW |
7.5kW |
Rated Output Voltage
|
380~460Vac (3PH)
|
380~460Vac (3PH) |
380~460Vac (3PH) |
380~460Vac (3PH) |
380~460Vac (3PH) |
380~460Vac (3PH) |
Frequency output range
|
0~50/60Hz
|
0~50/60Hz |
0~50/60Hz |
0~50/60Hz |
0~50/60Hz |
0~50/60Hz |
Rated output current
|
6A
|
7A |
9A |
10A |
13A | 18A |
System |
|
|
|
|
|
|
Level of protection |
IP65
|
IP65 |
IP65 |
IP65 |
IP65 |
IP65 |
Operating ambient temperature range
|
-25~60℃
|
-25~60℃ |
-25~60℃ |
-25~60℃ |
-25~60℃ |
-25~60℃ |
Type of cooling
|
natural cooling
|
natural cooling |
natural cooling |
natural cooling |
natural cooling |
natural cooling |
Display
|
LCD
|
LCD |
LCD |
LCD |
LCD |
LCD |
Communication
|
RS485/GPRS
|
RS485/GPRS |
RS485/GPRS |
RS485/GPRS |
RS485/GPRS |
RS485/GPRS |
Altitude
|
3000m, downscaling operation above 3000m
|
3000m, downscaling operation above 3000m |
3000m, downscaling operation above 3000m |
3000m, downscaling operation above 3000m |
3000m, downscaling operation above 3000m |
3000m, downscaling operation above 3000m |
Noise
|
<50dB
|
<50dB |
<50dB |
<50dB |
<50dB |
<50dB |
Meet acriterion
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800 |
EN 50178; IEC/EN 62109-1;IEC61800 |
EN 50178; IEC/EN 62109-1;IEC61800 |
EN 50178; IEC/EN 62109-1;IEC61800 |
EN 50178; IEC/EN 62109-1;IEC61800 |
Specification size (W/H/D)
|
265/330/150(mm)
|
265/330/150(mm) |
265/330/150(mm) |
265/330/150(mm) |
265/330/150(mm) |
265/330/150(mm) |
Weight
|
11.8kg
|
11.8kg |
11.8kg |
11.8kg |
11.8kg |
11.8kg |
ISO9001, IS014001, OHSAS18001,TUV,CE,AAA credit management system,Third level qualification of power project construction, National high-tech enterprises