Introduction
Solar pumping inverter obtains DC electric energy from the photovoltaic cell and converts it into electric energy
to drive the water pump. According to the intensity of sunlight, the inverter adopts MPPT algorithm to adjust the
output frequency and make maximum use of solar energy.
SWP series solar pumping inverter is a flexible, easy-to-use and economical solar pumping inverter launched by
Days energy according to the differentiated needs of customers. It aims to provide customers with economic and
comprehensive economic benefit solutions.
Brand:
Dyas energyItem NO.:
SWP seriesPayment:
FOBProduct Origin:
Anhui, ChinaColor:
BlueShipping Port:
Nanjing, Ningbo, Shanghai,Shenzhen,GuangzhouLead Time:
7 daysSystem application:
Solar Pump Solution is mainly used in the fields of daily life water, agricultural and forestry irrigation, desert management, livestock water, village and town water supply, sewage treatment engineering and fountain landscape.
MAIN FUNCTION
1.Overvoltage and undervoltage protection
2.Overcurrent and short circuit protection
3.Output phase loss protection
4.0Pump drying protection
5.Water tank overflow protection
VFD parameter
Item \Model
|
SWP750L-E-V1
|
SWP1K5L-E-V1
|
SWP2K2L-E-V1
|
SWP4KL-E-V1
|
SWP750H-E-V1
|
SWP1K5H-E-V1
|
SWP2K2H-E-V1
|
PV Input
|
|
|
|
|
|
|
|
Max. input DC voltage
|
450Vdc
|
450Vdc
|
450Vdc
|
450Vdc
|
800Vdc
|
800Vdc
|
800Vdc
|
Recommended MPPT Voltage
|
150~450Vdc
|
150~450Vdc
|
150~450Vdc
|
150~450Vdc
|
485~750Vdc
|
485~750Vdc
|
485~750Vdc
|
Max. MPPT Effiffifficiency
|
99%
|
99%
|
99%
|
99%
|
99%
|
99%
|
99%
|
Number of String
|
1 | 1 | 1 | 1 | 1 | 1 | 1 |
A.C. Input
|
190~240Vac(1PH) When PV and power grid are required to be mixed,accessory products need to be added
|
190~240Vac(1PH) When PV and power grid are required to be mixed,accessory products need to be added |
190~240Vac(1PH) When PV and power grid are required to be mixed,accessory products need to be added |
190~240Vac(1PH) When PV and power grid are required to be mixed,accessory products need to be added |
330~460Vac(3PH) When PV and power grid are required to be mixed, accessory products need to be added
|
330~460Vac(3PH) When PV and power grid are required to be mixed, accessory products need to be added
|
330~460Vac(3PH) When PV and power grid are required to be mixed, accessory products need to be added
|
Frequency
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
A.C. Output
|
|
|
|
|
|
|
|
Max. applicable motor output power
|
0.75kW
|
1.5kW
|
2.2kW
|
4kW
|
0.75kW
|
1.5kW
|
2.2kW
|
Rated Output Voltage
|
220-240Vac 3PH
|
220-240Vac 3PH
|
220-240Vac 3PH,can drive 0.75kW/1.1kW single pahse pump
|
220-240Vac 3PH,can drive 1.5kW/2.2kW
single pahse pump
|
380-460Vac 3PH
|
380-460Vac 3PH
|
380-460Vac 3PH
|
Output Frequency Range
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
Rated output current
|
4A
|
7A
|
10A | 16A | 2.5A | 3.7A | 5A |
Mechanical data
|
|
|
|
|
|
|
|
Dimensions(W/H/D)(mm)
|
252/195/230
|
252/195/230
|
252/195/230
|
315/235/253
|
540/310/295
|
540/310/295
|
540/310/295
|
Weight
|
2kg | 2kg | 2.5kg | 4.3kg | 2kg | 3kg | 3kg |
System
|
|
|
|
|
|
|
|
Protection Level
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
Operating Temperature
|
-25℃ to +50℃,above 50℃ need derate operating
|
-25℃ to +50℃,above 50℃ need derate operating
|
-25℃ to +50℃,above 50℃ need derate operating
|
-25℃ to +50℃,above 50℃ need derate operating
|
-25℃ to +50℃,above 50℃ need derate operating
|
-25℃ to +50℃,above 50℃ need derate operating
|
-25℃ to +50℃,above 50℃ need derate operating
|
Cooling Way
|
Force cooling
|
Force cooling
|
Force cooling
|
Force cooling
|
Force cooling
|
Force cooling
|
Force cooling
|
Display
|
LED
|
LED
|
LED
|
LED
|
LED
|
LED
|
LED
|
Communication interface
|
RS485
|
RS485
|
RS485
|
RS485
|
RS485
|
RS485
|
RS485
|
Altitude
|
1000m; above 1000m need derate operating
|
1000m; above 1000m need derate operating
|
1000m; above 1000m need derate operating
|
1000m; above 1000m need derate operating
|
1000m; above 1000m need derate operating
|
1000m; above 1000m need derate operating
|
1000m; above 1000m need derate operating
|
Noise Emission
|
<65dB
|
<65dB
|
<65dB
|
<65dB
|
<65dB
|
<65dB
|
<65dB
|
Compliance
|
EN 50178; IEC/EN 62109-1; IEC 61800
|
EN 50178; IEC/EN 62109-1; IEC 61800
|
EN 50178; IEC/EN 62109-1; IEC 61800
|
EN 50178; IEC/EN 62109-1; IEC 61800
|
EN 50178; IEC/EN 62109-1; IEC 61800
|
EN 50178; IEC/EN 62109-1; IEC 61800
|
EN 50178; IEC/EN 62109-1; IEC 61800
|